Edge-lighting 2x150W/12V Dual Feed Surface Mount Magnetic Transf User Manual

Browse online or download User Manual for Lighting Edge-lighting 2x150W/12V Dual Feed Surface Mount Magnetic Transf. Edge Lighting 2x150W/12V Dual Feed Surface Mount Magnetic Transformer User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 5
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
M2T-2X150-12-P-_
Installation Instructions for Monorail 2 Circuit 2 X 150
120 Volt Input to 12 Volt
Single Feed Output
Watt Extended
Surface Mount Magnetic Transformer
1
904-M2T-2X150-12-P-05
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
®
© 2013 Edge Lighting. All Rights Reserved.
SAVE THESE INSTRUCTIONS!
- Do not install this lighting system in a damp or wet
location.
- Do not conceal or extend bus bar conductor through
building wall.
- To reduce the risk of fire and burns, do not install this
lighting system where the insulated open bus bar
conductors can be shorted or contact any conductive
materials.
- To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
- Do not install fixture assemblies closer than six inches, or
as specified in the fixture installation instructions, to
curtains or similarly combustible materials.
- Turn the electrical power off before modifying the lighting
system in any way.
- The fixtures used with the Edge Lighting systems must be
identified for use with the corresponding Edge Lighting
systems.
- Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeters).
- The system is "ETL" listed for USA and Canada only when
all the products used are supplied by Edge Lighting.
- RISK OF FIRE: This product must be installed by a
qualified electrician. Turn the power to the electrical box off
during installation. Read the "Important Safety Instructions"
before installation.
- This product is suitable only for indoor dry locations and
approved for the use at any height above the finished floor.
- This product contains a magnetic transformer with a built-in
dimming coil.
- This product may be dimmed only with a low voltage
magnetic dimmer. Using a dimmer other than specified may
work initially, but will eventually cause transformer failure
and void the warranty. The dimmer must be derated as
indicated by the dimmer manufacturer.
- A typical installation is shown. Specific installation must be
in accordance with the local electrical codes.
- Load each circuit of the surface mount transformer to
MAXIMUM 150 Watt.
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - Watt Extended

M2T-2X150-12-P-_Installation Instructions for Monorail 2 Circuit 2 X 150 120 Volt Input to 12 Volt Single Feed OutputWatt Extended Surface Mount Magne

Page 2

HOUSING SET SCREW 2Install the Surface Mount Transformer1: Loosen and remove the five M4 button head screws around the transformer cover with the

Page 3

310: Feed the extension wires through the transformer housing center hole. Slide the transformer housing onto the crossbar assembly nipple

Page 4

4CAP3/8-24 SETSCREWPOWER HOUSING12MIDDLECONTACTKNURLEDNUT31: Unscrew the cap from the power housing.2: Slightly loosen the 3/8-24 set screw on the cap

Page 5

5N1: Remove the wire nuts from the center wires.2: Loosen (DO NOT REMOVE) the bottom M3 set screw on the bushing and carefully pull out the power