MT-300-24-P-_
Installation Instructions for Monorail
120 Volt Input to 24 Volt Single
Feed Output
300 Watt Extended Surface
Mount Magnetic Transformer
1
904-MT-300-24-P-03
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
SAVE THESE INSTRUCTIONS!
- Do not install this lighting system in a damp or wet
location.
- Do not conceal or extend bus bar conductor through
building wall.
- To reduce the risk of fire and burns, do not install this
lighting system where the insulated open bus bar
conductors can be shorted or contact any conductive
materials.
- To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
- Do not install fixture assemblies closer than six inches, or
as specified in the fixture installation instructions, to
curtains or similarly combustible materials.
- Turn the electrical power off before modifying the lighting
system in any way.
- The fixtures used with the Edge Lighting systems must be
identified for use with the corresponding Edge Lighting
systems.
- Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeters).
- The system is "ETL" listed for USA and Canada only when
all the products used are supplied by Edge Lighting.
- RISK OF FIRE: This product must be installed by a
qualified electrician. Turn the power to the electrical box off
during installation. Read the "Important Safety Instructions"
before installation.
- This product is suitable only for indoor dry locations and
approved for the use at any height above the finished floor.
- This product contains a magnetic transformer with a built-in
dimming coil.
- This product may be dimmed only with a low voltage
magnetic dimmer. Using a dimmer other than specified may
work initially, but will eventually cause transformer failure
and void the warranty. The dimmer must be derated as
indicated by the dimmer manufacturer.
- A typical installation is shown. Specific installation must be
in accordance with the local electrical codes.
- Load the circuit of the surface mount transformer to
MAXIMUM 300 Watt.
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
PATENT PENDING
© 2012 Edge Lighting. All Rights Reserved.
Page view 0
1 2 3 4 5

Summary of Contents

Page 1 - Mount Magnetic Transformer

MT-300-24-P-_Installation Instructions for Monorail 120 Volt Input to 24 Volt Single Feed Output300 Watt Extended Surface Mount Magnetic Transformer 1

Page 2

2Install the Surface Mount Transformer1: Loosen and remove the five M4 button head screws around the transformer cover with the provided 2mm Allen

Page 3

39: Feed the extension wires through the transformer housing center hole. Slide the transformer housing onto the crossbar assembly nipple and

Page 4

P14Install the Monorail to the TransformerIPOWER HOUSING3/8-24 SET SCREWNOTE:the Monorail while connecting Monorail to the surface mount transformer (

Page 5

POWER FEED RODM3 SET SCREW1.5MM ALLEN WRENCHBUSHING5L1: Remove the wire nut from the center wire.2: Loosen (DO NOT REMOVE) the bottom M3 set screw on